Opened 18 months ago

Last modified 15 months ago

#108 closed requirement

Anschlüsse an Elektronikgehäuse — at Version 3

Reported by: (none) Owned by: Erik Welander
Priority: major Component: Elektronikgehäuse
Keywords: Cc:
Data type: Deadline:
Depending on: 11 Implements:
Memaddress: Observerlist:
Parent: #95 Answer:
Type: construction Revieweraccept:
Reviewerlist: welander Reviewerreject:
Priority: normal Visibility:
Writable: Class: constraint
Priority: must have

Description (last modified by Erik Welander)

Das Elektronikgehäuse muss außer den in Anf #11 spezifizierte Signale auch

16 x Anschlüsse für Sensoren (jeweils 2-polig)

nach Außen führen.

Change History (3)

comment:1 by Erik Welander, 17 months ago

Depending on: 11
Description: modified (diff)
Reporter: Erik Welander removed

comment:2 by Markus Hantzsch, 17 months ago

Mit Sensoren sind hier wahrscheinlich die Ultraschall-Transducer gemeint.
Für maximal 8 Messpfade müssen es dann 16 Anschlüsse sein (jeweils 2-polig).

in reply to:  2 comment:3 by Erik Welander, 17 months ago

Description: modified (diff)

Replying to hantzsch:

Mit Sensoren sind hier wahrscheinlich die Ultraschall-Transducer gemeint.
Für maximal 8 Messpfade müssen es dann 16 Anschlüsse sein (jeweils 2-polig).

Ja, das stimmt, danke!

Note: See TracTickets for help on using tickets.