Korrosionsschutz

Reported by: (none) Owned by: Erik Welander
Priority: major Component: Gesamtsystem
Keywords: Cc:
Data type: Deadline:
Depending on: 179 Implements:
Memaddress: Observerlist:
Parent: #138 Answer:
Type: system Revieweraccept:
Reviewerlist: rotaru,rummler Reviewerreject: rotaru
Priority: normal Visibility:
Writable: Class: functional
Priority: must have

Description (last modified by Erik Welander)

Der Zählerkörper soll mindestens einen Korrosionsschutz C3 nach ISO 12944 haben.

Hinweis:
Dies entspricht GT400 und bezieht sich auf Wetterschutz. Für Bauteile die in Kontakt mit dem Betriebsgas kommen, gelten andere Anforderungen (i.e. 93).

Change History (6)

comment:1 by Erik Welander, 16 months ago

Description: modified (diff)
Reporter: Erik Welander removed

comment:2 by Erik Welander, 14 months ago

Description: modified (diff)

comment:3 by Erik Welander, 14 months ago

Description: modified (diff)
Reviewerlist: welanderrotaru,rummler
Status: newsubmitted

comment:4 by Erik Welander, 13 months ago

Type: constructionsystem

comment:5 by Erik Welander, 13 months ago

Depending on: 179

comment:6 by Rotaru, Sebastian, 13 months ago

Reviewerreject: rotaru

Das wäre für mich ok. Wobei ich glaube der aktuelle Anstrich für GT400 stellt keine Schutzklasse C3 nach ISO12944 dar. Also Achtung! Sonst machen wir das neue Produkt teurer als nötig und schaffen zusätzlich etwas, das am Std. Farbanstrich vorbeiläuft.