Opened 16 months ago

Last modified 10 months ago

#164 new requirement

Korrosionsschutz

Reported by: (none) Owned by: Erik Welander
Priority: major Milestone:
Component: Gesamtsystem Severity:
Keywords: Cc:
Data type: Deadline:
Depending on: 179 Implements:
Memaddress: Observerlist:
Parent: #138 Answer:
Type: system Revieweraccept:
Reviewerlist: rotaru,rummler Reviewerreject:
Priority: normal Visibility:
Writable: Class: functional
Criticality: must have

Description (last modified by Erik Welander)

Der Zählerkörper soll mindestens einen Korrosionsschutz C3 nach ISO 12944 haben.

Hinweis:
Dies entspricht GT400 und bezieht sich auf Wetterschutz. Für Bauteile die in Kontakt mit dem Betriebsgas kommen, gelten andere Anforderungen (i.e. 93).

Change History (7)

comment:1 by Erik Welander, 16 months ago

Description: modified (diff)
Reporter: Erik Welander removed

comment:2 by Erik Welander, 14 months ago

Description: modified (diff)

comment:3 by Erik Welander, 14 months ago

Description: modified (diff)
Reviewerlist: welanderrotaru,rummler
Status: newsubmitted

comment:4 by Erik Welander, 13 months ago

Type: constructionsystem

comment:5 by Erik Welander, 13 months ago

Depending on: 179

comment:6 by Rotaru, Sebastian, 13 months ago

Reviewerreject: rotaru

Das wäre für mich ok. Wobei ich glaube der aktuelle Anstrich für GT400 stellt keine Schutzklasse C3 nach ISO12944 dar. Also Achtung! Sonst machen wir das neue Produkt teurer als nötig und schaffen zusätzlich etwas, das am Std. Farbanstrich vorbeiläuft.

comment:7 by Benjamin Rummler, 10 months ago

Reviewerreject: rotaru
Status: submittednew

Egal welcher mindeststandard definiert wird, er muss der ISO 12944 unterliegen. Von daher wäre schon gut, zumindest C2 lang/high vorzusehen. Diese Schutzklasse kann man in manchen Farbsystemen (Fa. HEMPEL) schon mit einer Lackschicht erreicht werden.

Last edited 10 months ago by Benjamin Rummler (previous) (diff)
Note: See TracTickets for help on using tickets.