Opened 13 months ago
Last modified 8 weeks ago
#257 modified requirement
Erstellung eigener Modbus (Server) Userliste — at Version 13
| Reported by: | (none) | Owned by: | Rotaru, Sebastian |
|---|---|---|---|
| Priority: | major | Milestone: | |
| Component: | Plattform | Severity: | |
| Keywords: | Cc: | Rotaru, Sebastian, David Meister | |
| Data type: | Deadline: | ||
| Depending on: | 182 | Implements: | |
| Memaddress: | Observerlist: | ||
| Parent: | #10 | Answer: | |
| Type: | system | Revieweraccept: | |
| Reviewerlist: | welander,rotaru | Reviewerreject: | |
| Priority: | normal | Visibility: | |
| Writable: | Class: | functional | |
| Criticality: | important |
Description (last modified by )
Es muss möglich sein, selber mehrere Modbus Userlisten über mindestens 100 Werte zu erstellen.
Unterschiedliche Schnittstellen für Modbus Server (COM1, COM2, Eth1, Eth2, Wi-Fi, etc) sollen gleichzeitig unterschiedliche Userlisten verwenden können (mind. 1 pro Schnittstelle). Zum Beispiel soll es möglich sein Instanz-F auf COM1 und Eth1 zu verwenden und gleichzeitig eine selbst erstellte Userliste auf Eth2. Es ist nicht notwendig, dass mehrere Userlisten auf eine Schnittstelle gleichzeitig verwendet werden können. Zum Beispiel könnte die aktive Userliste für eine Schnittstelle aus einem Dropdownmenü über alle angelegte Userlisten ausgewählt werden.
Die Userlisten sollen, für jeden in der Liste spezifizierten Koordinatewert (typischerweise Anzeigewert), eine Modbusadresse zuordnen.
Anwendungsfall ist für Kundenspezifische Geräte die über voreingestellten Modbusadressen Daten auslesen.
Beispiel:
Kundengerät holt Durchfluss immer über Modbusadresse 1234 und Schallgeschwindigkeit immer über Modbusadresse 5678. Die Userliste muss damit die Verknüpfungen
- 'Koordinate für Durchfluss' : Adresse 1234
- 'Koordinate für Schallgeschwindigkeit' : Adresse 5678
beinhalten.
Siehe auch das Plattformprojekt.
Change History (13)
comment:1 by , 11 months ago
| Criticality: | must have → important |
|---|---|
| Depending on: | → 142 |
| Description: | modified (diff) |
| Reporter: | removed |
| Reviewerlist: | welander → welander,rotaru |
| Status: | new → submitted |
| Type: | software → system |
comment:2 by , 11 months ago
| Depending on: | 142 → 182 |
|---|
comment:3 by , 11 months ago
| Parent: | → #7 |
|---|
comment:4 by , 11 months ago
| Revieweraccept: | → welander |
|---|
comment:5 by , 10 months ago
| Status: | submitted → accepted |
|---|
comment:6 by , 10 months ago
| Revieweraccept: | welander |
|---|---|
| Status: | accepted → modified |
comment:7 by , 10 months ago
| Component: | Bediensoftware → Plattform |
|---|---|
| Description: | modified (diff) |
| Parent: | #7 → #344 |
| Status: | modified → resubmitted |
comment:8 by , 9 months ago
| Parent: | #344 → #10 |
|---|
comment:9 by , 7 months ago
| Revieweraccept: | → rotaru |
|---|
comment:10 by , 5 months ago
| Status: | resubmitted → accepted |
|---|
comment:11 by , 5 months ago
| Revieweraccept: | rotaru |
|---|---|
| Status: | accepted → modified |
comment:12 by , 5 months ago
| Description: | modified (diff) |
|---|---|
| Summary: | Erstellung eigener Modbus Liste → Erstellung eigener Modbus (Server) Userliste |
comment:13 by , 8 weeks ago
| Cc: | added; removed |
|---|---|
| Description: | modified (diff) |
![(please configure the [header_logo] section in trac.ini)](/rsm600_req/chrome/site/rmglogo.png)